DC Contactors Your PositionㄩHome >> Product Introduction >> HV DC Contactors GL250
HV DC Contactors GL250
Product NameㄩHV DC Contactors GL250
Item NoㄩGL250
Descriptionㄩ

Sealed HV DC/AC Contactor - 250Amp Power Switching 

RoHS Compliant

HV DC Contactors GL250  Download
Product Details Introduction

FEATURES
  • Ceramic to metal seal rated to 175⊥ 每 Reduced risk of fire or meltdown in over-current conditions.
  • Hermetic Seal 每 Designed to meet UL1604 for Class I & II, Div 2 and Class III for use in hazardous locations, IP67 for temporary water immersion for 30 min, SAE J1171 - external ignition protection, and ISO8846 for protection against ignition around flammable gasses.
  • High Efficiency Coils 每 CCoil with PWM economizer can lower power cost and it limits back EMF to 0V. The contactor can keep contact with very low coil power supply.
  • No Exposed Coil Electronics 每 The GL250 can operate almost anywhere, even under water 每 the coil electronics is fully sealed.
  • Fully RoHS Compliant 每 The GL250 is fully compliant and is better for the environment and future generations.

Product specifications
Parameter Ratings
Contact Arrangement (main) SPST-NO
Rated Operating Voltage 12-750VDC/VAC
Rated carrying current 250A ㄗ4/0 cable- 107mm2 cross-section areaㄘ
Max carrying current (1time) 1 Second ,1600A, 60 Seconds, 480Aㄛ600 Seconds,320A 
See Figure 2. Current carrying capacity
Switching Capacity See Figure 1. Power switching capacity for resistive load
Max cut-off current 1600A@320VDCㄛ1 time
Contact Resistance
Max @ rated carry current
Typical @ 150A

0.4m次
0.3m次
Mechanical Life 300ㄛ000 Cycles
Operate time, 25˚C
Close (includes bounce) Max
Close (includes bounce) Typical
Bounce on close, Max
Release time (includes arc time at max. break current)

20ms
13 ms
7 ms
12 ms
Contact Arrangement (Auxilary) SPST-NOㄗThe auxiliary contact is mechanically linked to the main power contacts.ㄘ
Auxiliary contact rating 2A@24VDC
Minimum current and voltage for Auxiliary contact 100mA@8V
Insulation Resistance at 500VDC 100 M次 ㄗ50 M次 after life testㄘ
Dielectric at sea level (leakage < 1mA) 2200 VRMS
Shock (Saw tooth or 1/2 Sine,11ms) 20G*s
Vibration, Sinusoidal (10-2000 Hz peak) 20G*s
Operating ambient Temp Range -55-85⊥
Storage ambient Temp Range -55⊥-125⊥
Weight, Typical 0.38kg/(0.84Lb)ㄗwithout nuts/washersㄘ


Power switching capacity for resistive load

Figure 1 . Power switching capacity for resistive load


Noteㄩ
1. Electrical life rating is based on resistive load with 27米H maximum inductance in circuit. Because your application may be different, we suggest you test the contactor in your circuit to verify life is as required.
End of life is defined as when the dielectric, insulation resistance or contact resistance exceeds the specifications listed.
2. Contactor is connected by 4/0 cables (107mm2 cross-section area).


Current carrying capacity

Figure 2﹜Current Carrying capacity


Coil ratings
Coil P/N Designation A or 1 D
Coil Voltage (Will operate) 10-36Vdc 32-95Vdc
Coil Voltage (Max) 36Vdc 95Vdc
In-Rush Current Max (100 ms) 每 Amps 3.6A 0.9A
Hold Current after in-rush (Avg.) - Amps 0.13A@12Vdc,
0.07A@24Vdc
0.04A@48Vdc
Pick-up Voltage @ 25C, Max 8.5V 32V
Dropout Voltage @ 25C, Min 4.5V 20V

Ratings are valid over temperature range .


Part number system
GL250 A A A N A
Contact Form:
A=Normally Open, H=Normally Open with Aux. Contacts
Coil voltage:
A=10-36vdc
D=32-95vdc
1=10-36VDC (requires external coil economizer)
Coil Wire Length:
A=15.3 in (390mm) B=6.0 in (150mm)
Coil Terminal Connector:
N=None
Mounting & Power Terminals:
A=Bottom Mount & Male 10mm X M8 Terminals


Electrical load life ratings for typical EV application

Power voltage 320VDC
Make life at 90% capacitive pre-charge 50,000 cycles ㄗSee figure 3ㄘ
Make life at 80% capacitive pre-charge 50 cycles
Make/break life at reversed 200A 12 cycles
Maximum break capacity
ㄗpositive directionㄘ
1600A , one time. 
Does not meet dielectric and IR after test﹝
Noteㄩ 
1.Resistive load includes inductance L≒27米H. 
2.Life based on projected Weibull life with 95% reliability.

Figure 3﹜Make test curves for pre charged capacitive load at 320VDC
Outline dimension


Application Information:
  1. WARNING - When using more than one lug on a power terminal, make sure the primary power is closest to the contactor busbar, with the lower current lug on top, then the washer, then the lock washer, then the nut.Improper order can cause severe over-heating resulting in the possible melting of the connecting cable insulation.

Prevㄩ HV DC Contactors GL150 Nextㄩ HV DC Contactors GL350
About Us News Center Products Show Service Center Contact Us
Company Profile
Company Culture
Company History
Certification
Company Honor
Company News Vacuum Capacitors
DC Contactors
AC Contactor
HV Relays
Vacuum Interrupters
Magnetrons
Service Promises
Sales Advisory
Contact Us
Recruitment
Old Factory: +86(512)-57735621
Free Hotline: +86(512)-36872110 / +86(512)-36872112
E-mail: e-sales@glvac.cn / quality@glvac.cn
Fax: +86-0512-36872122 / +86-0512-57777020
Technical Hotline: +86-0512-36872147 / +86-0512-57772785
Address: ST28 Xihu Road, Kunshan, Jiangsu Province,China.
Copyright @ 2013-2016 Kunshan GuoLi Electronic Technology Co., Ltd. All Rights Reserved.   Tel: +86( 512 )57735621 / +86( 512 )57772785   E-mail: e-sales@glvac.cn / quality@glvac.cn